Ice Storage System
Ice Storage System

 Ice storage system applications:

 

Suitable for electricity load is relatively concentrated, large changes in places such as :: 

· large hotels, hotels 

· high-rise buildings, large commercial center 

· large exhibition hall, exhibition center, arts and culture museum 

· station waiting room, airport terminal 

· stadiums, theaters, concert halls 

· large-scale production plant, or constant standardized production workshop 

· dairy products, pasta and meat processing plant 

· emergency equipment the environment, computer rooms, military facilities, telephone room and flammable materials warehouse

 

Ice storage system advantages:

· peak load shifting, peak grid load balancing; 

· reduce chiller and other equipment power system, the total electricity load is small, reducing the power capacity costs, while reducing the corresponding power equipment investment, such as: transformers, power distribution cabinets, etc.; 

· Since the system equipment capacity reduction, thus reducing the engine room equipment maintenance costs; 

· use TOU poor, reducing the running costs of air-conditioning systems; 

· make the device a larger proportion of full-load operation, fully improve equipment utilization and efficiency and running stability; 

· can be used as an emergency source of cold, reducing standby power system investment; 

· reduce the effective area of chiller plant, ice storage equipment can be flexibly placed in outdoor, underground, the roof and other places; 

· use of flexible, holidays, part of the region used to provide air conditioning load by melting ice, energy-saving effect is obvious; may be smaller loads (such as using only individual regions) quantitative melting ice cooling, without having to open the host; 

· Start time is short, short time to reach the desired temperature, while the conventional system will need about 1 hour; 

· ice storage system with a large temperature difference between the system and the cold air system combine to further reduce the initial investment, improve air quality, increase the air conditioning comfort.

 

Uruk ice storage system advantages: 

· the device manufacturing process has experienced at least three 400Psi airtightness test, effectively ensure the reliability of the equipment; 

· Incomplete freeze mode, tube row was no internal stress, wedge-shaped design, effectively prevent excessive ice damage to the coil, long life; 

· single coil lengths up to 100 meters, continuous welded together, sealed performance is good, durable, suitable for steel tanks or concrete tank; 

· device is not completely frozen, there is provided a stable temperature of melting ice, which applies to such a large temperature difference and cold air conditioning system; 

· Steel Round serpentine coil heat transfer efficiency, melting ice temperature stability; 

· coil diameter large heat exchange area per unit length, ice quantity; 

· long flow heat exchangers, heat exchange is fully within the coil was turbulent state, high efficiency heat exchange; 

· Equipment designed and manufactured to comply with ASHRAE, ARI and ASME standards.

 

 

Uruk ice storage system technology and R & D:

 

 

Design and development 

· have ice storage equipment testing and R & D platform for modern R & D center 

· by the International Energy R & D team composed of experts 

· a variety of standard models of ice storage equipment 

· perfect ice storage equipment technology selection 

· Accurate ice storage equipment measured data ThermalRFinned 

Left: Schematic diagram of peak load shifting 

 

Patented technology 

Snowman ice storage equipment has "Extra-PakTM" technical features, and has the following patents: 

· Efficient heat exchange coil patented technology (Thermal-ParkR Coil U.S. Patent No.: 4,755,311) 

· efficient heat exchanger fin coil patented technology (Thermal-ParkR Finned Coil U.S. Patent No.: 5,425,414) 

 

Coil loop 

- When the coil circuit design ice storage equipment must be considered a problem, snowman ice coil circuit using countercurrent manner (Figure 3), which can be achieved between the rows of each tube icing evenly, stable characteristic melting ice . Wedge-shaped design, effectively prevent excessive ice damage to the coil, is more conducive to icing way not completely frozen. 

 

Coil structure 

Uruk ice coil is 100 m long continuous longitudinal butt weld without elliptical serpentine coil, connected in parallel with the same way, in the form of counter-current arrangement fixed to the frame structure, the overall process for the hot-dip zinc ice storage equipment . 

- From melting ice at the bottom of the device is also equipped with PVC air distribution piping, and can be installed on the device side ice deflector design of this two structures more effectively ensure the stability of the ice-melting properties.

 

 

  

 

 

           Countercurrent loop cone ice                                                            Uruk coil loop

 

 

Water Treatment 

- Because the water around the world have different quality of ice water in the system is very important. First ice, the ice bath water temperature to remain near zero. At this temperature, there will be micro-organisms or the formation of scale. In addition, almost no water consumption caused due to evaporation, water is generally not required. 

In order to ensure good water quality, water treatment processes required to meet the following criteria: 

 ph of 6.5-8.5;  Chlorides ≤ 100ppm;  Sulphate ≤ 250ppm;  alkali ≤ 500ppm;  dissolved solids ≤ 1000ppm. 

- Water treatment additives must be used with caution in order to avoid changing the nature of the water freezes. 

- Snowman ice storage devices without automatic water treatment program. As long as the initial injection of water to obtain and meet the above criteria, periodic water quality monitoring (once or twice a year) can be. According to the type of ice storage systems and processes, usually tested once a year is sufficient. However, due to different water quality and the environment, it may require more frequent monitoring. Water should be chemically analyzed and decide whether to proceed with treatment. 

 

Glycol 

- Glycol solution of water and a mixture of ethylene glycol or propylene glycol, to be used frost protection. To protect the air conditioning system used in metal materials (copper, brass and steel), corrosion inhibitors should be used with two types of glycol industrial grade products. Glycol normal life of approximately 20 years, or longer, which is about the validity of inhibitors 7-10 years. 

- The Dow Chemical Company Product DOWTHERM SR-1 (ethylene glycol) and DOWFOROST HD (propylene glycol) are applicable to steel ice coil. Other products that meet the above requirements can also be accepted. 

- Can be purchased pre-mixed glycol solution, you can buy with the inhibitor concentration of 97% ethylene glycol solution, mixed on site. Usually pre-mixed solution of ethylene glycol, the inhibitor and deionized water. Require on-site mixing glycol, deionized water in the absence of the case, high-quality drinking water can be used instead. 

 

Ice coil 

- Snowman ice coil has a variety of specifications, while providing guaranteed amount of ice in different sizes to meet the needs of users, a single device can 30RTh to 383RTh